Aerial Work Platform Machinery

Electric Aerial Work Platform Bases: Procurement, Acceptance Testing and Documentation

Buying an aerial work platform base is a compliance purchase as much as an equipment purchase. The base carries people, it operates at height, and it will be inspected by someone other than the buyer. The specification, the test evidence and the documentation package matter as much as the working height and the platform capacity.

This guide sets out what to specify, what to test before acceptance, and what documents to demand with delivery.

Quick answer

A complete aerial base procurement package has four parts: a specification that states rated capacity, working height, platform dimensions, travel speed, gradeability and drive type; a pre-delivery test record covering load test, stability, brake performance and electrical insulation; a documentation set including drawings, load charts, maintenance manual and conformity evidence; and a site acceptance test performed by the buyer before final payment. Missing any one of the four is how projects end up with a machine that cannot be put into service.

Why the electric drive changes the procurement checklist

A diesel or petrol platform base is procured mainly on mechanical criteria. An electric base adds a battery system, a charger, a motor controller and often a battery management system. Each of those introduces a specification field and a test that a mechanical machine does not need.

CriterionWhat to specifyWhy it matters
Battery chemistry and capacitykWh and chemistry, with the usable fraction statedDetermines shift capability; usable fraction is often much less than nominal
Charging time and charger inputHours to full charge; charger voltage and currentDetermines whether the machine fits a single-shift or multi-shift pattern
Duty cycle statementContinuous, intermittent or defined raises per hourElectric drive thermal limits are duty-cycle dependent
Regenerative brakingWhether fitted and how it interacts with the brake systemAffects brake wear and energy recovery
Insulation monitoringWhether an insulation fault monitor is fittedA traction battery on a steel structure needs fault detection
Emergency lowering with power lossManual or stored-energy methodRequired for operator rescue; must be documented
Ingress protection of the electrical enclosureIP rating of the controller and battery boxOutdoor and wash-down exposure
Electrical criteria that appear only with an electric base.

The specification fields that must be unambiguous

Ambiguity in these fields is where disputes come from. Each one should be stated with a value and a tolerance.

FieldState it asCommon ambiguity
Rated capacitykg, with the number of persons allowedWhether the figure includes tools and materials
Working heightm, measured from ground to platform floorWhether it is platform height or working height (1.8 – 2 m difference)
Platform dimensionsLength x width in mm, with the extension lengthWhether the extension is included in the rated capacity
Travel speedkm/h, raised and lowered separatelyWhether the figure is at full load
GradeabilityPercent grade, ladenWhether it is at full load and on a specified surface
Turning radiusInside and outside radius in mmWhether it is with or without the platform extended
Wheelbase and trackmmRarely stated; critical for site access
Ground bearing pressurekPa or kg/cm²Almost never stated; the most common cause of site refusal
Noise leveldB(A) at operator positionMeasured distance rarely stated
Battery enduranceHours or raises, with duty statedWhether measured at full load
Specification fields, with the ambiguity each one typically hides.

Pre-delivery tests the buyer should witness or require evidence of

TestMethodEvidence to require
Rated load testApply rated load; operate through full envelopeSigned test record with load, duration and observations
Overload testApply the specified overload percentage; confirm no permanent deformationTest record with the percentage and inspection result
Stability testOperate at rated load on the maximum specified slopeRecord with slope angle and load
Brake performanceMeasure stopping distance laden on the specified gradeMeasured data, not a statement
Emergency loweringSimulate power loss; operate the emergency loweringRecord with time to lower and method used
Insulation testMeasure insulation resistance of the traction circuitMeasured value with the instrument identified
Function testEvery control at every position, including interlocksChecklist with each function ticked
Tilt and level cut-outOperate on a slope beyond the limit; confirm the cut-out operatesRecord with the slope at which the cut-out triggered
Tests and the evidence to require for each.

The documentation package

The documentation package should be listed in the purchase order as a deliverable, not requested later. A machine without the package is a machine that cannot be inspected or maintained to a defensible standard.

  1. General arrangement drawing with dimensions and weight.
  2. Load chart or rated capacity table, including the extension condition.
  3. Electrical schematic with wire identification and component references.
  4. Hydraulic schematic if the platform has hydraulic functions.
  5. Operation manual in the language of the destination market.
  6. Maintenance manual with service intervals and torque values.
  7. Parts list with part numbers for wear items.
  8. Test records for each item in the pre-delivery list.
  9. Battery specification sheet and charger instructions.
  10. Declaration of conformity or equivalent, where the destination market requires it.

Site acceptance test: the buyer's own verification

The site acceptance test is not a repeat of the factory test. It verifies that the machine as delivered, in the buyer's conditions, behaves as specified.

TestAcceptance criterionWhat a failure indicates
Full envelope operation at rated loadAll functions operate smoothly, no alarmsAssembly or commissioning error
Stability on the steepest site slopeNo cut-out triggered below the stated limitCut-out set point wrong, or stated limit overstated
Gradeability trialClimbs the stated grade laden without stallingMotor or controller undersized for the specification
Battery endurance trialMeets the stated shift capability at site dutyEndurance overstated, or duty cycle misunderstood
Brake test on site surfaceStopping distance within the stated figureBrake adjustment, or surface assumption wrong
Emergency loweringOperates within the documented timeStored energy depleted, or valve fault
Control response at full extensionNo lag or jitterController tuning or wiring issue
Noise measurementWithin the specified level at the operator positionHydraulic or drive noise above specification
Site acceptance test items and acceptance criteria.

Ground bearing pressure: the specification omission that stops projects

Ground bearing pressure is rarely stated in a quotation, and it is frequently the reason a platform cannot be used on the site it was bought for.

Site surfaceIndicative bearing capacityImplication
Reinforced concrete slabHighMost platforms acceptable
Compacted hardcoreModerateCheck point loads at the outriggers or wheels
Asphalt over sub-baseModerate, temperature dependentSummer softening can reduce capacity sharply
Graded soilLowLoad spreading mats likely required
Suspended slab or basement roofStructure dependentRequires a structural assessment, not a seat-of-pants judgement
Why ground bearing pressure needs to be checked before purchase.

Ask the supplier for the laden point load at each wheel or outrigger. That number, not the total machine weight, is what the site engineer needs.

Commercial terms that protect the buyer

  • Tie final payment to successful site acceptance, not to delivery.
  • Require the documentation package as a deliverable with a stated delivery date.
  • State a spare parts availability period, for example ten years from delivery.
  • Require the supplier to state the service interval and the maintenance tasks the buyer can perform in-house.
  • Define the warranty response time and the location of the service point.
  • For export orders, agree the language of manuals and labels before manufacture, not after.

Frequently asked questions

What is the difference between platform height and working height?

Platform height is the height of the platform floor above ground. Working height adds a nominal reach allowance, commonly about 2 metres. Buying on platform height when you need working height is a frequent and expensive error.

Can an electric base work a full shift?

That depends on the battery capacity and the duty cycle. Ask for the endurance figure at full load with the duty cycle stated, and trial it on site before rolling out across a fleet.

Is a load test required before every use?

No. A full load test is a commissioning and periodic inspection item. Pre-use checks cover controls, brakes, emergency lowering and obvious damage.

What documentation should travel with the machine?

At minimum the operation manual, load chart, maintenance schedule and test records. For most markets, the conformity documentation is also required for the machine to be legal to operate.

How is gradeability affected by load?

Directly. A machine rated at a grade laden should be tested laden. Ratings quoted unladen are not usable for site planning.

Should outriggers be required for all work at height?

Not for all, but the conditions under which outriggers are required should be stated in the specification and the operation manual, not left to operator judgement.

What is a reasonable warranty period for an electric base?

Twelve months on the whole machine and a longer period on the battery, where the battery is a defined-capacity item, is a common structure. The critical variable is the response time, not the headline duration.

}

Planning the site before delivery

A platform that arrives without the right charging infrastructure and site layout loses its first weeks of productivity. Our site integration guide covers power supply, charging workflow and surface preparation.

Read the guide →

Need a seat matched to your machine?

Send us the mounting dimensions, vehicle model and operating conditions. We will confirm the suspension type, adjustment range and mounting plate that fit, and quote accordingly.

Request a quote →